Genomics Facility

Campus I Campus II Campus III

RGCB has a centralized Genomics facility to meet the demand of scientists in various research fields. This facility is greatly helping their research work, catering to the sequencing needs of the Institute. Services include DNA sequencing, Genotyping using DNA analyzers, Real time PCR, Microarray and Droplet digital PCR.

DNA Analyzer

Automated DNA Sequencing Facility is equipped with 3730 DNA Analyzer (48 capillary high throughput DNA Sequencer) and 3730xL DNA Analyzer (96 capillary high throughput DNA Sequencer). The fluorescence-based DNA sequencing systems, with capillary electrophoresis is having 96 capillaries operating in parallel for Sanger sequencing. The system automatically performs sample injection, gel matrix replacement, DNA separation, detection, and data analysis. This system sequence 48-96 samples in 2 hours' time and perform up to 12 runs per day. Average read length with big dye terminator (BDT) chemistry is 800 bp. This system can also be used for fragment analysis, AFLP, genotyping and SNP analysis.

Real Time PCR & Droplet Digital PCR

The facility equipped with RealTime PCRs (Quantstudio 5, 0.2 ml 96 & 384 well systems, 7900HT Real-Time with TLDA, and droplet digital PCR (QX 100-Biorad). The systems can be used for

  1. Absolute quantitation
  2. Relative quantitation
  3. Plus /minus assay
  4. Taqman Low density (TLDA)
  5. Copy number variation studies

Additional information

The Core accepts DNA samples (pure plasmids, mini-prep plasmids, M13 clones, cosmids, lambda clones, PCR products, gel isolated fragments, bacterial genomic), sequenced PCR products, and processes them according to protocols for Applied Biosystems DNA Sequencers (BDT Chemistry). One sequencing run (one template, one primer) typically produces 700-800 nucleotides of high-quality sequence data or more for good quality template and a well-designed primer. The results are returned in three forms: a raw sequence file, sequence with blue score and a chromatogram file. The sequence file (a flat ASCII text file) is returned to the researcher by electronic mail.

Each sequencing plate includes at least one lane of standard DNA known to generate good sequence. The sample handling and data analysis are extremely reliable and have a very low rate of error. If any problems are indicated in our sample processing, we repeat the affected samples on request. We typically process samples within two days after receipt. Samples are processed Monday through Friday for overnight instrument runs. The data are processed and returned by email to the users.

Contact

Rajiv Gandhi Centre for Biotechnology (RGCB),
Thycaud Post, Poojappura,
Thiruvananthapuram - 695 014, Kerala, India
+91-471-2529400 | 2347975 | 2348753
info@rgcb.res.in webmaster@rgcb.res.in

My Gov www.mygov.in Prime Ministers National Relife Fund India Gov www.india.gov.in Make In India www.makeinindia.gov.in Make In India www.iredibleindia.org Data gov in www.data.gov.in www.pib.gov.in

Last Updated on: December 20, 2024
CERT-In Certified Website